1G SFP
1Gbps transmission
Applications
- Ethernet (100M/ 1G)
- ESCON/ FICON
- 1G Fiber channel
- Multi-rate 100Mbps to 1.25Gbps
Small Form Pluggable (SFP) Transceiver Modules available with:
- Copper SFP Modules (10/100/1000 and 1000)
- Dual Fiber Strands SFP Modules
- CWDM Dual Fiber Strands SFP Modules
- C and L Band DWDM Dual Fiber Strands SFP Modules
- Single Fiber Strand (Bi-Di) SFP Modules
- Supports various wavelengths such as 850nm, 1300nm, 1310nm, 1550nm, CWDM and DWDM, and distances up to 160km for 100Mbps and 120km for 1Gbps
- Digital Diagnostic Monitoring (DDM) for optical monitoring capability compliant with SFF-8472 (Internal/ External Calibration)
- Supports Normal Operating Temperature 0 to +70 or Industrial Operating Temperature -40 to +85 degree Celsius
- Compatible to major equipment vendors (Coding)
- 2 years warranty with optional extended warranty up to 5 years
Ordering Information
Temperature Option : Standard temperature – 0°C to +70°C; Industrial temperature – -40°C to +85°C
Copper SFP Modules
Dual Fiber Strands SFP Modules
CWDM Dual Fiber Strands SFP Modules
C and L band DWDM Dual Fiber Strands SFP Modules
Single Fiber Strand SFP Modules
Copper SFP Modules
Standard
Industrial
Standard
Standard
| Data Rate | Part Number | Type | Wavelength | Distance (km) | TX Power (dBm) | RX Sens. (dBm) | Fiber Budget (dB) |
|---|---|---|---|---|---|---|---|
| SFP-T1A | 0.1 | ||||||
| 10/100/1000Mb/s | SFP-T1B | 0.1 | |||||
| SFP-T1C | 0.1 | ||||||
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-T2A | 0.1 | ||||||
| 1000Mb/s | SFP-T2B | 0.1 | |||||
| SFP-T2C | 0.1 |
Industrial
Industrial
| Data Rate | Part Number | Type | Wavelength | Distance (km) | TX Power (dBm) | RX Sens. (dBm) | Fiber Budget (dB) |
|---|---|---|---|---|---|---|---|
| SFP-T1AH | 0.1 | ||||||
| 10/100/1000Mb/s | SFP-T1BH | 0.1 | |||||
| SFP-T1CH | 0.1 | ||||||
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-T2AH | 0.1 | ||||||
| 1000Mb/s | SFP-T2BH | 0.1 | |||||
| SFP-T2CH | 0.1 |
Dual Fiber Strands SFP Modules
Standard
Industrial
Standard
Standard
| Data Rate | Part Number | Type | Wavelength | Distance (km) | TX Power (dBm) | RX Sens. (dBm) | Fiber Budget (dB) |
|---|---|---|---|---|---|---|---|
| SFP-OC3M8D | MM | 850nm | 2 | -9 to -3 | -24 to -6 | 12 | |
| SFP-OC3MD | MM | 1300nm | 2 | -20 to -14 | -28 to -8 | 5 | |
| 100Mb/s | SFP-OC3SD2 | SM | 1310nm | 20 | -15 to -8 | -29 to -8 | 14 |
| (FE / STM-1 / | SFP-OC3SD4 | SM | 1310nm | 40 | -7 to -2 | -32 to -10 | 25 |
| OC-3) | SFP-OC3SD8 | SM | 1550nm | 80 | -5 to 0 | -33 to -10 | 28 |
| SFP-OC3SD12 | SM | 1550nm | 120 | -2 to 3 | -34 to -10 | 32 | |
| SFP-OC3SD16 | SM | 1550nm | 160 | 1 to 5 | -37 to -10 | 36 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-OC12SD2 | SM | 1310nm | 20 | -15 to -8 | -28 to -8 | 13 | |
| 622 Mb/s | SFP-OC12SD4 | SM | 1310nm | 40 | -5 to 0 | -28 to -8 | 23 |
| (STM-4 / OC- | SFP-OC12SD8 | SM | 1550nm | 80 | -3 to 2 | -28 to -8 | 25 |
| 12) | SFP-OC12SD12 | SM | 1550nm | 120 | 0 to 5 | -31 to -8 | 31 |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-SXD | MM | 850nm | 0.22 | -9 to -3 | -17 to 0 | 5 | |
| SFP-ESXD | MM | 1300nm | 2 | -5 to 0 | -20 to 0 | 15 | |
| SFP-LXD1 | SM | 1310nm | 10 | -9 to -3 | -20 to -3 | 11 | |
| 1.25 Gb/s | SFP-LXD2 | SM | 1310nm | 20 | -9 to -3 | -20 to -3 | 11 |
| (Gbe / FC) | SFP-LXD4 | SM | 1310nm | 40 | -5 to 0 | -24 to -1 | 19 |
| SFP-ZXD6 | SM | 1550nm | 60 | 0 to 5 | -26 to -3 | 26 | |
| SFP-ZXD8 | SM | 1550nm | 80 | 0 to 5 | -26 to -3 | 26 | |
| SFP-ZXD12 | SM | 1550nm | 120 | 0 to 5 | -31 to -10 | 31 | |
| SFP-ZXD16 | SM | 1550nm | 160 | 2 to 6 | -34 to -10 | 36 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-2GSXD | MM | 850nm | 0.3 | -10 to -3 | -18 to -3 | 5 | |
| SFP-2GLXD | SM | 1310nm | 2 | -9 to -3 | -18 to -3 | 9 | |
| Multi-rate | SFP-2GLXD1 | SM | 1310nm | 10 | -5 to 0 | -19 to 0 | 14 |
| 2.125 Gbps/s to | SFP-2GLXD2 | SM | 1310nm | 20 | -5 to 0 | -19 to 0 | 14 |
| 2.7 Gb/s | SFP-2GLXD4 | SM | 1310nm | 40 | -2 to 3 | -19 to 0 | 17 |
| SFP-2GZXD4 | SM | 1550nm | 40 | -2 to 3 | -19 to 0 | 17 | |
| SFP-2GZXD8 | SM | 1550nm | 80 | 0 to 5 | -28 to -6 | 28 | |
| SFP-2GZXD12 | SM | 1550nm | 120 | 1 to 6 | -30 to -10 | 31 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-4GSXD | MM | 850nm | 0.55 | -9 to -2.5 | -16 to 0 | 4 | |
| Multi-rate | SFP-4GLXD | SM | 1310nm | 2 | -6 to -1 | -18 to 0.5 | 12 |
| 100Mb/s to | SFP-4GLXD1 | SM | 1310nm | 10 | -6 to -1 | -18 to 0.5 | 12 |
| 4.25Gb/s | SFP-4GLXD2 | SM | 1310nm | 20 | -6 to -1 | -18 to 0.5 | 12 |
| SFP-4GLXD4 | SM | 1310nm | 40 | -1 to 4 | -18 to 0.5 | 17 |
Industrial
Industrial
| Data Rate | Part Number | Type | Wavelength | Distance (km) | TX Power (dBm) | RX Sens. (dBm) | Fiber Budget (dB) |
|---|---|---|---|---|---|---|---|
| SFP-OC3M8DH | MM | 850nm | 2 | -9 to -3 | -24 to -6 | 12 | |
| SFP-OC3MDH | MM | 1310nm | 2 | -20 to -14 | -28 to -8 | 5 | |
| 100Mb/s | SFP-OC3SD2H | SM | 1310nm | 20 | -15 to -8 | -29 to -8 | 14 |
| (FE / STM-1 / | SFP-OC3SD4H | SM | 1310nm | 40 | -7 to -2 | -32 to -10 | 25 |
| OC-3) | SFP-OC3SD8H | SM | 1550nm | 80 | -5 to 0 | -33 to -10 | 28 |
| SFP-OC3SD12H | SM | 1550nm | 120 | -2 to 3 | -34 to -10 | 32 | |
| SFP-OC3SD16H | SM | 1550nm | 160 | 1 to 5 | -37 to -10 | 36 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-OC12SD2H | SM | 1310nm | 20 | -15 to -8 | -28 to -8 | 13 | |
| 622 Mb/s | SFP-OC12SD4H | SM | 1310nm | 40 | -5 to 0 | -28 to -8 | 23 |
| (STM-4 / OC- | SFP-OC12SD8H | SM | 1550nm | 80 | -3 to 2 | -28 to -8 | 25 |
| 12) | SFP-OC12SD12H | SM | 1550nm | 120 | 0 to 5 | -31 to -8 | 31 |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-SXDH | MM | 850nm | 0.22 | -9 to -3 | -17 to 0 | 5 | |
| SFP-ESXDH | MM | 1300nm | 2 | -5 to 0 | -20 to 0 | 15 | |
| SFP-LXD1H | SM | 1310nm | 10 | -9 to -3 | -20 to -3 | 11 | |
| 1.25 Gb/s | SFP-LXD2H | SM | 1310nm | 20 | -9 to -3 | -20 to -3 | 11 |
| (Gbe / FC) | SFP-LXD4H | SM | 1310nm | 40 | -5 to 0 | -24 to -1 | 19 |
| SFP-ZXD6H | SM | 1550nm | 60 | 0 to 5 | -26 to -3 | 26 | |
| SFP-ZXD8H | SM | 1550nm | 80 | 0 to 5 | -26 to -3 | 26 | |
| SFP-ZXD12H | SM | 1550nm | 120 | 0 to 5 | -31 to -10 | 31 | |
| SFP-ZXD16H | SM | 1550nm | 160 | 2 to 6 | -34 to -10 | 36 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-2GSXDH | MM | 850nm | 0.3 | -10 to -3 | -18 to -3 | 5 | |
| SFP-2GLXDH | SM | 1310nm | 2 | -9 to -3 | -18 to -3 | 9 | |
| Multi-rate | SFP-2GLXD1H | SM | 1310nm | 10 | -5 to 0 | -19 to 0 | 14 |
| 2.125 Gbps/s to | SFP-2GLXD2H | SM | 1310nm | 20 | -5 to 0 | -19 to 0 | 14 |
| 2.7 Gb/s | SFP-2GLXD4H | SM | 1310nm | 40 | -2 to 3 | -19 to 0 | 17 |
| SFP-2GZXD4H | SM | 1550nm | 40 | -2 to 3 | -19 to 0 | 17 | |
| SFP-2GZXD8H | SM | 1550nm | 80 | 0 to 5 | -28 to -6 | 28 | |
| SFP-2GZXD12H | SM | 1550nm | 120 | 1 to 6 | -30 to -6 | 31 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-4GSXDH | MM | 850nm | 0.55 | -9 to -2.5 | -16 to 0 | 4 | |
| Multi-rate | SFP-4GLXDH | SM | 1310nm | 2 | -6 to -1 | -18 to 0.5 | 12 |
| 100Mb/s to | SFP-4GLXD1H | SM | 1310nm | 10 | -6 to -1 | -18 to 0.5 | 12 |
| 4.25Gb/s | SFP-4GLXD2H | SM | 1310nm | 20 | -6 to -1 | -18 to 0.5 | 12 |
| SFP-4GLXD4H | SM | 1310nm | 40 | -1 to 4 | -18 to 0.5 | 17 |
CWDM Dual Fiber Strands SFP Modules
Standard
Standard
Standard
| Data Rate | Part Number | Type | Wavelength | Distance (km) | TX Power (dBm) | RX Sens. (dBm) | Fiber Budget (dB) |
|---|---|---|---|---|---|---|---|
| 100Mb/s | SFP-OC3SD12C## | SM | 1470nm ~ 1610nm | 120 | -2 to 3 | -34 to -10 | 32 |
| (FE / STM-1 / OC-3) | SFP-OC3SD16C## | SM | 1450nm ~ 1610nm | 160 | 0 to 5 | -35 to -10 | 35 |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| 1.25 Gb/s | SFP-ZXD4C## | SM | 1270nm ~ 1610nm | 40 | -5 to 0 | -24 to -1 | 19 |
| (Gbe / FC) | SFP-ZXD8C## | SM | 1270nm ~ 1610nm | 80 | 0 to 5 | -26 to -3 | 26 |
| SFP-ZXD12C## | SM | 1270nm ~ 1610nm | 120 | 0 to 5 | -32 to -10 | 32 | |
| SFP-ZXD16C## | SM | 1470nm ~ 1610nm | 160 | 2 to 6 | -34 to -10 | 36 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| Multi-rate | SFP-2GZX4CD## | SM | 1270nm ~ 1610nm | 40 | -2 to 3 | -19 to 0 | 17 |
| 100Mb/s to 2.488 Gb/s | SFP-2GZX8CD## | SM | 1270nm ~ 1610nm | 80 | 0 to 5 | -28 to -9 | 28 |
| SFP-2GZX12CD## | SM | 1470nm ~ 1610nm | 120 | 2 to 6 | -30 to -10 | 32 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| Multi-rate | SFP-4GZXD4C## | SM | 1310nm ~ 1610nm | 40 | -1 to 4 | -18 to 0.5 | 17 |
## denotes wavelength range from 1270~1610nm.
27 = 1270nm, 29=1290nm, 31=1310nm, 33=1330nm, 35=1350nm, 37=1370nm, 39=1390nm, 41=1410nm, 43=1430nm, 45=1450nm, 47=1470nm, 49=1490nm, 51=1510nm, 53=1530nm, 55=1550nm,57=1570nm, 59=1590nm, 61=1610nm
C and L band DWDM Dual Fiber Strands SFP Modules
100GHz Spacing DWDM
50 GHz Spacing DWDM
100GHz Spacing DWDM
100GHz Spacing DWDM
| Data Rate | Part Number | Type | Wavelength | Distance (km) | TX Power (dBm) | RX Sens. (dBm) | Fiber Budget (dB) |
|---|---|---|---|---|---|---|---|
| Multi-rate | SFP-ZXD8D## | SM | DWDM Wavelength | 80 | 0 to 4 | -26 to -10 | 26 |
| 100Mb/s to 1.25 Gb/s | SFP-ZXD12D## | SM | DWDM Wavelength | 120 | 0 to 5 | -30 to -10 | 30 |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| Multi-rate | SFP-2GZXD8D## | SM | DWDM Wavelength | 80 | 0 to 4 | -28 to -10 | 28 |
| 100Mb/s to 2.67Gb/s | SFP-2GZXD12D## | SM | DWDM Wavelength | 120 | 0 to 5 | -29 to -9 | 29 |
## denotes wavelength Guide
| ## ITU Channel | Wavelength | Frequency (THz) | ## ITU Channel | Wavelength | Frequency (THz) | ## ITU Channel | Wavelength | Frequency (THz) | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 17 | 1563.86 | 191.7 | 17 | 1563.86 | 191.7 | 17.5 | 1563.45 | 191.75 | |||
| 18 | 1563.05 | 191.8 | 18 | 1563.05 | 191.8 | 18.5 | 1562.64 | 191.85 | |||
| 19 | 1562.23 | 191.9 | 19 | 1562.23 | 191.9 | 19.5 | 1561.83 | 191.95 | |||
| 20 | 1561.42 | 192 | 20 | 1561.42 | 192 | 20.5 | 1561.01 | 192.05 | |||
| 21 | 1560.61 | 192.1 | 21 | 1560.61 | 192.1 | 21.5 | 1560.2 | 192.15 | |||
| 22 | 1559.79 | 192.2 | 22 | 1559.79 | 192.2 | 22.5 | 1559.39 | 192.25 | |||
| 23 | 1558.98 | 192.3 | 23 | 1558.98 | 192.3 | 23.5 | 1558.58 | 192.35 | |||
| 24 | 1558.17 | 192.4 | 24 | 1558.17 | 192.4 | 24.5 | 1557.77 | 192.45 | |||
| 25 | 1557.36 | 192.5 | 25 | 1557.36 | 192.5 | 25.5 | 1556.96 | 192.55 | |||
| 26 | 1556.55 | 192.6 | 26 | 1556.55 | 192.6 | 26.5 | 1556.15 | 192.65 | |||
| 27 | 1555.75 | 192.7 | 27 | 1555.75 | 192.7 | 27.5 | 1555.34 | 192.75 | |||
| 28 | 1554.94 | 192.8 | 28 | 1554.94 | 192.8 | 28.5 | 1554.54 | 192.85 | |||
| 29 | 1554.13 | 192.9 | 29 | 1554.13 | 192.9 | 29.5 | 1553.73 | 192.95 | |||
| 30 | 1553.33 | 193 | 30 | 1553.33 | 193 | 30.5 | 1552.93 | 193.05 | |||
| 31 | 1552.52 | 193.1 | 31 | 1552.52 | 193.1 | 31.5 | 1552.12 | 193.15 | |||
| 32 | 1551.72 | 193.2 | 32 | 1551.72 | 193.2 | 32.5 | 1551.32 | 193.25 | |||
| 33 | 1550.92 | 193.3 | 33 | 1550.92 | 193.3 | 33.5 | 1550.52 | 193.35 | |||
| 34 | 1550.12 | 193.4 | 34 | 1550.12 | 193.4 | 34.5 | 1549.72 | 193.45 | |||
| 35 | 1549.32 | 193.5 | 35 | 1549.32 | 193.5 | 35.5 | 1548.91 | 193.55 | |||
| 36 | 1548.51 | 193.6 | 36 | 1548.51 | 193.6 | 36.5 | 1548.11 | 193.65 | |||
| 37 | 1547.72 | 193.7 | 37 | 1547.72 | 193.7 | 37.5 | 1547.32 | 193.75 | |||
| 38 | 1546.92 | 193.8 | 38 | 1546.92 | 193.8 | 38.5 | 1546.52 | 193.85 | |||
| 39 | 1546.12 | 193.9 | 39 | 1546.12 | 193.9 | 39.5 | 1545.72 | 193.95 | |||
| 40 | 1545.32 | 194 | 40 | 1545.32 | 194 | 40.5 | 1544.92 | 194.05 | |||
| 41 | 1544.53 | 194.1 | 41 | 1544.53 | 194.1 | 41.5 | 1544.13 | 194.15 | |||
| 42 | 1543.73 | 194.2 | 42 | 1543.73 | 194.2 | 42.5 | 1543.33 | 194.25 | |||
| 43 | 1542.94 | 194.3 | 43 | 1542.94 | 194.3 | 43.5 | 1542.54 | 194.35 | |||
| 44 | 1542.14 | 194.4 | 44 | 1542.14 | 194.4 | 44.5 | 1541.75 | 194.45 | |||
| 45 | 1541.35 | 194.5 | 45 | 1541.35 | 194.5 | 45.5 | 1540.95 | 194.55 | |||
| 46 | 1540.56 | 194.6 | 46 | 1540.56 | 194.6 | 46.5 | 1540.16 | 194.65 | |||
| 47 | 1539.77 | 194.7 | 47 | 1539.77 | 194.7 | 47.5 | 1539.37 | 194.75 | |||
| 48 | 1538.98 | 194.8 | 48 | 1538.98 | 194.8 | 48.5 | 1538.58 | 194.85 | |||
| 49 | 1538.19 | 194.9 | 49 | 1538.19 | 194.9 | 49.5 | 1537.79 | 194.95 | |||
| 50 | 1537.4 | 195 | 50 | 1537.4 | 195 | 50.5 | 1537 | 195.05 | |||
| 51 | 1536.61 | 195.1 | 51 | 1536.61 | 195.1 | 51.5 | 1536.22 | 195.15 | |||
| 52 | 1535.82 | 195.2 | 52 | 1535.82 | 195.2 | 52.5 | 1535.43 | 195.25 | |||
| 53 | 1535.04 | 195.3 | 53 | 1535.04 | 195.3 | 53.5 | 1534.64 | 195.35 | |||
| 54 | 1534.25 | 195.4 | 54 | 1534.25 | 195.4 | 54.5 | 1533.86 | 195.45 | |||
| 55 | 1533.47 | 195.5 | 55 | 1533.47 | 195.5 | 55.5 | 1533.07 | 195.55 | |||
| 56 | 1532.68 | 195.6 | 56 | 1532.68 | 195.6 | 56.5 | 1532.29 | 195.65 | |||
| 57 | 1531.9 | 195.7 | 57 | 1531.9 | 195.7 | 57.5 | 1531.51 | 195.75 | |||
| 58 | 1531.12 | 195.8 | 58 | 1531.12 | 195.8 | 58.5 | 1530.72 | 195.85 | |||
| 59 | 1530.33 | 195.9 | 59 | 1530.33 | 195.9 | 59.5 | 1529.94 | 195.95 | |||
| 60 | 1529.55 | 196 | 60 | 1529.55 | 196 | 60.5 | 1529.16 | 196.05 | |||
| 61 | 1528.77 | 196.1 | 61 | 1528.77 | 196.1 |
50 GHz Spacing DWDM
50 GHz Spacing DWDM
| Data Rate | Part Number | Type | Wavelength | Distance (km) | TX Power (dBm) | RX Sens. (dBm) | Fiber Budget (dB) |
|---|---|---|---|---|---|---|---|
| Multi-rate | SFP-ZXD8AD## | SM | DWDM Wavelength | 80 | 0 to 4 | -26 to -3 | 26 |
| 100Mb/s to 1.25 Gb/s | SFP-ZXD12AD## | SM | DWDM Wavelength | 120 | 0 to 5 | -30 to -6 | 30 |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| Multi-rate | SFP-2GZXD8AD## | SM | DWDM Wavelength | 80 | 0 to 4 | -28 to -9 | 28 |
| 100Mb/s to 2.67Gb/s | SFP-2GZXD12AD## | SM | DWDM Wavelength | 120 | 2 to 5 | -31 to -9 | 33 |
## denotes wavelength Guide
| ## ITU Channel | Wavelength | Frequency (THz) | ## ITU Channel | Wavelength | Frequency (THz) | ## ITU Channel | Wavelength | Frequency (THz) | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 17 | 1563.86 | 191.7 | 17 | 1563.86 | 191.7 | 17.5 | 1563.45 | 191.75 | |||
| 18 | 1563.05 | 191.8 | 18 | 1563.05 | 191.8 | 18.5 | 1562.64 | 191.85 | |||
| 19 | 1562.23 | 191.9 | 19 | 1562.23 | 191.9 | 19.5 | 1561.83 | 191.95 | |||
| 20 | 1561.42 | 192 | 20 | 1561.42 | 192 | 20.5 | 1561.01 | 192.05 | |||
| 21 | 1560.61 | 192.1 | 21 | 1560.61 | 192.1 | 21.5 | 1560.2 | 192.15 | |||
| 22 | 1559.79 | 192.2 | 22 | 1559.79 | 192.2 | 22.5 | 1559.39 | 192.25 | |||
| 23 | 1558.98 | 192.3 | 23 | 1558.98 | 192.3 | 23.5 | 1558.58 | 192.35 | |||
| 24 | 1558.17 | 192.4 | 24 | 1558.17 | 192.4 | 24.5 | 1557.77 | 192.45 | |||
| 25 | 1557.36 | 192.5 | 25 | 1557.36 | 192.5 | 25.5 | 1556.96 | 192.55 | |||
| 26 | 1556.55 | 192.6 | 26 | 1556.55 | 192.6 | 26.5 | 1556.15 | 192.65 | |||
| 27 | 1555.75 | 192.7 | 27 | 1555.75 | 192.7 | 27.5 | 1555.34 | 192.75 | |||
| 28 | 1554.94 | 192.8 | 28 | 1554.94 | 192.8 | 28.5 | 1554.54 | 192.85 | |||
| 29 | 1554.13 | 192.9 | 29 | 1554.13 | 192.9 | 29.5 | 1553.73 | 192.95 | |||
| 30 | 1553.33 | 193 | 30 | 1553.33 | 193 | 30.5 | 1552.93 | 193.05 | |||
| 31 | 1552.52 | 193.1 | 31 | 1552.52 | 193.1 | 31.5 | 1552.12 | 193.15 | |||
| 32 | 1551.72 | 193.2 | 32 | 1551.72 | 193.2 | 32.5 | 1551.32 | 193.25 | |||
| 33 | 1550.92 | 193.3 | 33 | 1550.92 | 193.3 | 33.5 | 1550.52 | 193.35 | |||
| 34 | 1550.12 | 193.4 | 34 | 1550.12 | 193.4 | 34.5 | 1549.72 | 193.45 | |||
| 35 | 1549.32 | 193.5 | 35 | 1549.32 | 193.5 | 35.5 | 1548.91 | 193.55 | |||
| 36 | 1548.51 | 193.6 | 36 | 1548.51 | 193.6 | 36.5 | 1548.11 | 193.65 | |||
| 37 | 1547.72 | 193.7 | 37 | 1547.72 | 193.7 | 37.5 | 1547.32 | 193.75 | |||
| 38 | 1546.92 | 193.8 | 38 | 1546.92 | 193.8 | 38.5 | 1546.52 | 193.85 | |||
| 39 | 1546.12 | 193.9 | 39 | 1546.12 | 193.9 | 39.5 | 1545.72 | 193.95 | |||
| 40 | 1545.32 | 194 | 40 | 1545.32 | 194 | 40.5 | 1544.92 | 194.05 | |||
| 41 | 1544.53 | 194.1 | 41 | 1544.53 | 194.1 | 41.5 | 1544.13 | 194.15 | |||
| 42 | 1543.73 | 194.2 | 42 | 1543.73 | 194.2 | 42.5 | 1543.33 | 194.25 | |||
| 43 | 1542.94 | 194.3 | 43 | 1542.94 | 194.3 | 43.5 | 1542.54 | 194.35 | |||
| 44 | 1542.14 | 194.4 | 44 | 1542.14 | 194.4 | 44.5 | 1541.75 | 194.45 | |||
| 45 | 1541.35 | 194.5 | 45 | 1541.35 | 194.5 | 45.5 | 1540.95 | 194.55 | |||
| 46 | 1540.56 | 194.6 | 46 | 1540.56 | 194.6 | 46.5 | 1540.16 | 194.65 | |||
| 47 | 1539.77 | 194.7 | 47 | 1539.77 | 194.7 | 47.5 | 1539.37 | 194.75 | |||
| 48 | 1538.98 | 194.8 | 48 | 1538.98 | 194.8 | 48.5 | 1538.58 | 194.85 | |||
| 49 | 1538.19 | 194.9 | 49 | 1538.19 | 194.9 | 49.5 | 1537.79 | 194.95 | |||
| 50 | 1537.4 | 195 | 50 | 1537.4 | 195 | 50.5 | 1537 | 195.05 | |||
| 51 | 1536.61 | 195.1 | 51 | 1536.61 | 195.1 | 51.5 | 1536.22 | 195.15 | |||
| 52 | 1535.82 | 195.2 | 52 | 1535.82 | 195.2 | 52.5 | 1535.43 | 195.25 | |||
| 53 | 1535.04 | 195.3 | 53 | 1535.04 | 195.3 | 53.5 | 1534.64 | 195.35 | |||
| 54 | 1534.25 | 195.4 | 54 | 1534.25 | 195.4 | 54.5 | 1533.86 | 195.45 | |||
| 55 | 1533.47 | 195.5 | 55 | 1533.47 | 195.5 | 55.5 | 1533.07 | 195.55 | |||
| 56 | 1532.68 | 195.6 | 56 | 1532.68 | 195.6 | 56.5 | 1532.29 | 195.65 | |||
| 57 | 1531.9 | 195.7 | 57 | 1531.9 | 195.7 | 57.5 | 1531.51 | 195.75 | |||
| 58 | 1531.12 | 195.8 | 58 | 1531.12 | 195.8 | 58.5 | 1530.72 | 195.85 | |||
| 59 | 1530.33 | 195.9 | 59 | 1530.33 | 195.9 | 59.5 | 1529.94 | 195.95 | |||
| 60 | 1529.55 | 196 | 60 | 1529.55 | 196 | 60.5 | 1529.16 | 196.05 | |||
| 61 | 1528.77 | 196.1 | 61 | 1528.77 | 196.1 |
Single Fiber Strand SFP Modules
Standard
Industrial
Standard
Standard
Industrial
Industrial
| Data Rate | Part Number | Type | Wavelength | Distance (km) | TX Power (dBm) | RX Sens. (dBm) | Fiber Budget (dB) |
|---|---|---|---|---|---|---|---|
| SFP-OC3SD21H | SM | 1310TX 1550RX | 20 | -15 to -7 | -28 to -8 | 13 | |
| SFP-OC3SD22H | SM | 1550TX 1310RX | 20 | -15 to -7 | -28 to -8 | 13 | |
| SFP-OC3SD41H | SM | 1310TX 1550RX | 40 | -7 to -2 | -32 to -8 | 25 | |
| SFP-OC3SD42H | SM | 1550TX 1310RX | 40 | -7 to -2 | -32 to -8 | 25 | |
| 100Mb/s | SFP-OC3SD61H | SM | 1310TX 1550RX | 60 | -5 to 0 | -33 to -10 | 28 |
| (FE / STM-1 / | SFP-OC3SD62H | SM | 1550TX 1310RX | 60 | -5 to 0 | -33 to -10 | 28 |
| OC-3) | SFP-OC3SD83H | SM | 1490TX 1550RX | 80 | -5 to 0 | -33 to -8 | 28 |
| SFP-OC3SD84H | SM | 1550TX 1490RX | 80 | -5 to 0 | -33 to -8 | 28 | |
| SFP-OC3SD123H | SM | 1490TX 1550RX | 120 | -2 to 3 | -34 to -10 | 32 | |
| SFP-OC3SD124H | SM | 1550TX 1490RX | 120 | -2 to 3 | -34 to -10 | 32 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-ESXD1H | SM | 1310TX 1550RX | 2 | -11 to -3 | -19 to -3 | 8 | |
| SFP-ESXD2H | SM | 1550TX 1310RX | 2 | -11 to -3 | -19 to -3 | 8 | |
| SFP-LXD11H | SM | 1310TX 1550RX | 10 | -9 to -3 | -20 to -3 | 11 | |
| SFP-LXD12H | SM | 1550TX 1310RX | 10 | -9 to -3 | -20 to -3 | 11 | |
| SFP-LXD13H | SM | 1310TX 1490RX | 10 | -9 to -3 | -20 to -3 | 11 | |
| SFP-LXD14H | SM | 1490TX 1310RX | 10 | -9 to -3 | -20 to -3 | 11 | |
| SFP-LXD21H | SM | 1310TX 1550RX | 20 | -9 to -3 | -20 to -3 | 11 | |
| SFP-LXD22H | SM | 1550TX 1310RX | 20 | -9 to -3 | -20 to -3 | 11 | |
| SFP-LXD23H | SM | 1310TX 1490RX | 20 | -9 to -3 | -20 to -3 | 11 | |
| 1.25 Gb/s | SFP-LXD24H | SM | 1490TX 1310RX | 20 | -9 to -3 | -20 to -3 | 11 |
| (Gbe) | SFP-LXD41H | SM | 1310TX 1550RX | 40 | -5 to 0 | -24 to 1 | 19 |
| SFP-LXD42H | SM | 1550TX 1310RX | 40 | -5 to 0 | -24 to 1 | 19 | |
| SFP-LXD43H | SM | 1310TX 1490RX | 40 | -5 to 0 | -24 to 1 | 19 | |
| SFP-LXD44H | SM | 1490TX 1310RX | 40 | -5 to 0 | -24 to 1 | 19 | |
| SFP-LXD61H | SM | 1310TX 1550RX | 60 | 0 to 5 | -26 to -3 | 26 | |
| SFP-LXD62H | SM | 1550TX 1310RX | 60 | 0 to 5 | -26 to -3 | 26 | |
| SFP-LXD81H | SM | 1310TX 1550RX | 80 | 0 to 5 | -26 to -3 | 26 | |
| SFP-LXD82H | SM | 1550TX 1310RX | 80 | 0 to 5 | -26 to -3 | 26 | |
| SFP-LXD85H | SM | 1550TX 1490RX | 80 | 0 to 5 | -26 to -3 | 26 | |
| SFP-LXD86H | SM | 1490TX 1550RX | 80 | 0 to 5 | -26 to -3 | 26 | |
| SFP-LXD125H | SM | 1550TX 1490RX | 120 | 0 to 5 | -31 to -10 | 31 | |
| SFP-LXD126H | SM | 1490TX 1550RX | 120 | 0 to 5 | -31 to -10 | 31 | |
| ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— | ———————— |
| SFP-2GLXD21H | SM | 1310TX 1550RX | 20 | -5 to 0 | -19 to -1 | 14 | |
| SFP-2GLXD22H | SM | 1550TX 1310RX | 20 | -5 to 0 | -19 to -1 | 14 | |
| Multi-rate | SFP-2GLXD41H | SM | 1310TX 1550RX | 40 | -2 to 3 | -19 to 0 | 17 |
| 100Mb/s to | SFP-2GLXD42H | SM | 1550TX 1310RX | 40 | -2 to 3 | -19 to 0 | 17 |
| 2.67Gb/s | SFP-2GLXD85H | SM | 1490TX 1550RX | 80 | 0 to 5 | -26 to -8 | 26 |
| SFP-2GLXD86H | SM | 1550TX 1490RX | 80 | 0 to 5 | -26 to -8 | 26 |